CDVQB - CJCS-11EE LEAD-ANTIMONY BATTERY
- MSDS: CDVQB
- Manufacturer: C AND D POWER SYSTEMS AN ALLIED CO
- Product Name: CJCS-11EE LEAD-ANTIMONY BATTERY
- National Stock Number: 6140-01-106-8936
Product Identification
Product ID:CJCS-11EE LEAD-ANTIMONY BATTERY
MSDS Date:01/30/1996
FSC:6140
NIIN:01-106-8936
Kit Part:Y
MSDS Number: CDVQB
Responsible Party
PLYMOUTH MEETING, PA 19462
US
Emergency Phone: 215-828-9000
Info Phone: 215-828-9000
Preparer: S.J. KELLY
Cage: 1K126
Contractor
Telephone: 804-266-9623
Cage: 7L867
Ingredients
LEAD (SARA 313) (CERCLA)
CAS: 7439-92-1
RTECS: OF7525000
Fraction By Weight: 59-62%
OSHA PEL SEE 1910.1025
ACGIH TLV: 0.05MG/M3, A3; 9596
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
ANTIMONY (SARA 313) (CERCLA)
CAS: 7440-36-0
RTECS: CC4025000
Fraction By Weight: 1-2%
OSHA PEL 0.5 MG/M3
ACGIH TLV: 0.5 MG (SB)/M3; 9596
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ARSENIC (SARA 313) (CERCLA)
CAS: 7440-38-2
RTECS: CG0525000
Fraction By Weight: <1%
OSHA PEL SEE 1910.1018
ACGIH TLV: 0.01 MG/M3, A1; 9596
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
COPPER (SARA 313) (CERCLA)
CAS: 7440-50-8
RTECS: GL5325000
Fraction By Weight: <1%
OSHA PEL 0.1MG/M3 FUME/1 DUST
ACGIH TLV: 0.2 MG/M3 FUME; 9596
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
INERT COMPONENTS
Fraction By Weight: 9-14%
Fire Fighting
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, HALON.
Fire Fighting Procedures:VENTILATE THE AREA WELL. SCBA AND ACID
PROTECTIVE CLOTHING ARE RECOMMENDED.
Unusual Fire/Explosion Hazard:HYDROGEN GAS MAY BE PRESENT. HYDROGEN GAS
AND ACID MIST IS GENERATED UPON OVERCHARGE OR IN FIRE. VENTILATE
AREA.
Exposure Controls
Supplemental Safety and Health
Chemical Properties
HCC:N1
Boiling Pt:B.P. Text:235F,113C
Vapor Pres:1
Vapor Density:>1
Spec Gravity:1.285
Evaporation Rate & Reference:<1 (WATER=1)
Solubility in Water:COMPLETE-ELECTROLYTE
Appearance and Odor:BATTERY, DRY CHARGED. 22 X 13 X 18 INCHES.
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ALKALIS, CONDUCTIVE METALS, ORGANIC MATERIALS.
Stability Condition to Avoid:SOLVENTS, SPARKS OR OPEN FLAME.
OVERHEATING, OVERCHARGING WHICH RESULT IN ACID MIST/HYDROGEN
GENERATION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.